VacuumFurnaces.com is a Q&A community where vacuum furnace product and service suppliers connect with commercial and captive heat treaters to share their practical skills and know-how and to establish valuable relationships around niche topics of expertise with vacuum furnace end-users in operations, production, training, maintenance, marketing, sales, and engineering.
Typically, the piping should be sized large enough so that frictional pressure drops within the piping system make up less than 10% of the operating pressure of the system. For example, a system operating at 100 psi should have less than 10 psi of frictional pressure losses in the piping system. PreRead more
Typically, the piping should be sized large enough so that frictional pressure drops within the piping system make up less than 10% of the operating pressure of the system. For example, a system operating at 100 psi should have less than 10 psi of frictional pressure losses in the piping system. Pressure losses in a piping system can be readily determined using the “equivalent length” method that is found in most piping handbooks. Since most piping systems are not complex, we have developed over the years a simple rule of thumb for sizing the piping. We generally recommend 5-10 feet per second in the supply pipe and 3-5 FPS in the return pipe.
Source: Dry Coolers
See less