VacuumFurnaces.com is a Q&A community where vacuum furnace product and service suppliers connect with commercial and captive heat treaters to share their practical skills and know-how and to establish valuable relationships around niche topics of expertise with vacuum furnace end-users in operations, production, training, maintenance, marketing, sales, and engineering.
How to size a vacuum booster pump for a vacuum chamber?
Sizing a vacuum booster pump for a vacuum chamber involves considering several key parameters and considerations to ensure that the pump can meet the vacuum requirements of the chamber. The size and capacity of the booster pump you need will depend on the specific characteristics of your vacuum systRead more
Sizing a vacuum booster pump for a vacuum chamber involves considering several key parameters and considerations to ensure that the pump can meet the vacuum requirements of the chamber. The size and capacity of the booster pump you need will depend on the specific characteristics of your vacuum system, including the chamber size, desired vacuum level, and the rate at which you need to evacuate the chamber.
Here’s a general guideline to help you size a vacuum booster pump:
1. Volume of the Vacuum Chamber:
2. Desired Vacuum Level:
3. Pumping Speed:
4. Process Throughput:
5. Backing (Primary) Pump Capacity:
6. Account for Gas Load:
7. Choose the Right Booster Pump:
8. Cooling Requirements:
9. Consider Additional Factors:
Remember that sizing a vacuum system accurately is crucial for achieving the desired vacuum level and maintaining the integrity of your vacuum chamber and the processes within it. Consulting with vacuum technology experts and pump manufacturers can help provide guidance based on your specific requirements and can provide detailed specifications, performance curves, and recommendations based on the specific requirements of your application.
See lessWhat are the key working principles of fore vacuum pumps?
Fore vacuum pumps are defined as those which exhaust to atmospheric pressure. They are also required to support secondary pumps or to attain the initial conditions for their operation. There are two types of fore vacuum pumps: Dry-running backing pumps such as scroll, screw and diaphragm pumps. Oil-Read more
Fore vacuum pumps are defined as those which exhaust to atmospheric pressure. They are also required to support secondary pumps or to attain the initial conditions for their operation. There are two types of fore vacuum pumps:
In this article, we’ll examine the key working principles of five (5) common fore vacuum pumps:
Source: Vacuum Science World
See lessHow do you properly conduct a Temperature Uniformity Survey (TUS)?
Ensuring that a furnace can perform repeatable and accurate cycles is a cornerstone of AMS2750E pyrometry specifications as well as Nadcap and CQI-9 standards. The best way to measure and test any furnace is through a temperature uniformity survey (TUS). These surveys are critically important, and wRead more
Ensuring that a furnace can perform repeatable and accurate cycles is a cornerstone of AMS2750E pyrometry specifications as well as Nadcap and CQI-9 standards. The best way to measure and test any furnace is through a temperature uniformity survey (TUS).
These surveys are critically important, and when working to meet a specification or standard, it’s critical to follow the requirements of that standard.
Source: Conrad Kacsik Instrument Systems Inc.
See lessWhat are the changes from AMS2750F to AMS2750G?
The changes from AMS2750F to AMS2750G include revisions and updates to the pyrometric requirements for equipment used in the thermal processing of metallic materials. The AMS2750G specification covers temperature sensors, instrumentation, thermal processing equipment, correction factors and instrumeRead more
The changes from AMS2750F to AMS2750G include revisions and updates to the pyrometric requirements for equipment used in the thermal processing of metallic materials. The AMS2750G specification covers temperature sensors, instrumentation, thermal processing equipment, correction factors and instrument offsets, system accuracy tests, and temperature uniformity surveys. These changes are necessary to ensure that parts or raw materials are heat treated in accordance with the applicable specifications. The purpose of AMS2750G is to ensure that parts or raw materials are heat treated in accordance with the applicable specifications.
The revision from AMS2750F to AMS2750G mainly consists of administrative changes rather than significant technical changes. One notable change is that digital recording instruments are not required to read to the tenth of a degree until one year after the release of AMS2750G. Additionally, over temperature controls have been given a permitted error within AMS2750G, which was not present in revision F.
To comply with AMS2750G, suppliers who already conform to AMS2750F should find the transition relatively straightforward. It is recommended to consult experts or training courses that specialize in AMS2750 standards and Nadcap requirements to ensure compliance. Calibration services and process certification services can also be helpful in meeting industry standards.
Some specific changes between AMS2750F and AMS2750G include:
Revision G marking: Historically, AMS2750 did not mark the revision when released using change bars, unlike other AMS specifications. However, when AMS2750F was revised to revision G, change bars were included. This makes it easier for suppliers to understand the modifications and account for those changes internally.
Extensive changes: AMS2750G is considered a complete rewrite of the specification, and there are no change bars to indicate specific changes. The changes are extensive and cover various aspects of pyrometry requirements.
It is important to refer to the official AMS2750G specification for a comprehensive understanding of all the changes and updates.
For more detailed information and updates on AMS2750G, you can visit the SAE International website or refer to the Conrad Kacsik blog post on the differences between AMS2750F and AMS2750G.
SOURCES:
Pyrometry AMS2750G – SAE International
Differences Between AMS2750F and AMS2750G – Conrad Kacsik
See lessHow do you achieve ultra-high vacuum levels?
In order to achieve ultra high vacuum conditions, special materials and pumping procedures are needed. Seals and gaskets used between components in a UHV system must prevent even trace leakage. Therefore, nearly all such seals are all metal, with knife-edges on both sides cutting into a soft gasket,Read more
In order to achieve ultra high vacuum conditions, special materials and pumping procedures are needed. Seals and gaskets used between components in a UHV system must prevent even trace leakage. Therefore, nearly all such seals are all metal, with knife-edges on both sides cutting into a soft gasket, typically copper. These all-metal seals can maintain integrity to UHV ranges.
Tips for achieving ultra-high pressure include:
Source: VAC AERO International – Pumps for High and Ultra-High Vacuum
See lessWhy is it important to use a clean and controlled environment in vacuum heat treatment?
Using a clean and controlled environment in vacuum heat treating is important for several reasons: 1. Contamination prevention: Vacuum heat treating involves subjecting materials to high temperatures in a controlled atmosphere. Any contaminants present in the environment can react with the materialRead more
Using a clean and controlled environment in vacuum heat treating is important for several reasons:
1. Contamination prevention:
Vacuum heat treating involves subjecting materials to high temperatures in a controlled atmosphere. Any contaminants present in the environment can react with the material or form unwanted surface layers, leading to discoloration or other quality issues. By maintaining a clean environment, the risk of contamination is minimized, ensuring the integrity of the heat-treated parts.
2. Consistent results:
A controlled environment helps in achieving consistent and repeatable results during the heat-treating process. Contaminants or impurities can introduce variability in the heat treatment process, leading to inconsistent outcomes. By eliminating or minimizing the presence of contaminants, the heat-treating process can be more predictable, resulting in consistent and reliable results.
3. Surface quality:
Cleanliness of the environment is crucial for achieving desired surface quality in heat-treated parts. Contaminants can cause surface imperfections, such as stains, discoloration, or pitting, which can affect the appearance and functionality of the parts. A clean environment helps maintain the desired surface finish and appearance of the heat-treated parts.
4. Material integrity:
Some materials are sensitive to contamination and can react with certain elements present in the environment. For example, reactive metals like titanium can easily react with oxygen, nitrogen, or carbon, leading to surface discoloration or degradation. By using a clean and controlled environment, the risk of such reactions can be minimized, preserving the integrity of the material.
5. Process efficiency:
A clean environment can contribute to the overall efficiency of the vacuum heat-treating process. Contaminants can interfere with heat transfer, affecting the uniformity of temperature distribution within the vacuum chamber. By ensuring a clean environment, heat can be transferred more efficiently, leading to faster and more effective heat treatment cycles.
In summary, using a clean and controlled environment in vacuum heat treating is essential to prevent contamination, achieve consistent results, maintain surface quality, preserve material integrity, and enhance process efficiency.
See lessWhat are the 5 signs of vacuum pump failure?
Even the most well-constructed vacuum pump can fail after extended use. In industrial applications, for instance, the downtime resulting from pump failures can be prohibitively expensive — especially if it forces production to grind to a halt. Knowing the signs of vacuum pump failure is crucial in mRead more
Even the most well-constructed vacuum pump can fail after extended use. In industrial applications, for instance, the downtime resulting from pump failures can be prohibitively expensive — especially if it forces production to grind to a halt.
Knowing the signs of vacuum pump failure is crucial in maintaining a functioning system and avoiding dangerous or expensive issues resulting from. Your maintenance plan should allow for the servicing, repair, and replacement of pumps. For smaller projects, this may involve sending pumps back to the manufacturer. With this in mind, here are the common signs of a failing vacuum pump:
Source: Vacuum Science World – What are the 5 signs of vacuum pump failure?
See lessWhat are the four basic rules for working under HV and UHV conditions?
When working with high vacuum (HV) and ultra-high vacuum (UHV), there are specific aspects to consider ensuring an efficient and safe system. To clarify, the pressure range of UHV conditions are defined as between 10-7 and 10-12 mbar, whereas HV conditions are defined as between 10-3 and 10-7 mbar.Read more
When working with high vacuum (HV) and ultra-high vacuum (UHV), there are specific aspects to consider ensuring an efficient and safe system.
To clarify, the pressure range of UHV conditions are defined as between 10-7 and 10-12 mbar, whereas HV conditions are defined as between 10-3 and 10-7 mbar. Some of the main applications of HV include metallurgical processes, nuclear physics, space simulation and analytical instruments. On the other hand, UHVs are used for surface analysis, in high-energy physics and Molecular Beam Epitaxy (MBE).
Here are the four main considerations you need to bear in mind when working under HV or UHV conditions.
Source: Vacuum Science World – Four basic rules for working under HV and UHV conditions.
See lessWhat are some of the main questions to ask when selecting a vacuum gauge?
When considering the purchase of a vacuum gauge, here are some of the basic questions to ask yourself: What pressure range are you looking for? What accuracy range are you seeking? Are there any other ranges that are important? Do you need to control or regulate, in addition to measuring? What formRead more
When considering the purchase of a vacuum gauge, here are some of the basic questions to ask yourself:
Source: Vacuum Gauges – VAC AERO International
See lessWhat are the main types of vacuum gauges?
Vacuum gauges are basic measurement components for vacuum furnace systems and can be found either in vacuum lines or connected directly onto the vacuum chamber. A vacuum gauge is an instrument for measuring pressures below that of atmospheric pressure. There are several types of vacuum gauges, eachRead more
Vacuum gauges are basic measurement components for vacuum furnace systems and can be found either in vacuum lines or connected directly onto the vacuum chamber. A vacuum gauge is an instrument for measuring pressures below that of atmospheric pressure. There are several types of vacuum gauges, each engineered for a specific function over a specific range of vacuum pressure.
Common types include:
Source: Vacuum Gauges – VAC AERO International
See lessIn any heat treating cycle, what are the main considerations concerning temperature?
In any heat treating cycle, there are two important considerations concerning temperature: the temperature of the furnace hot zone which is generating the heat input, and the temperature of the actual workload. Heating by direct radiation, the main heating mechanism in vacuum, tends to be a slower pRead more
In any heat treating cycle, there are two important considerations concerning temperature: the temperature of the furnace hot zone which is generating the heat input, and the temperature of the actual workload.
Heating by direct radiation, the main heating mechanism in vacuum, tends to be a slower process than other heating mechanisms such as convection or conduction. As a result, there are times in the heat treating cycle, particularly during heat up, when the load will be at a lower temperature than the furnace hot zone. This is known as temperature lag. Hot zone temperature is controlled and measured through two (or more) thermocouples located close to the heating elements. One thermocouple, the control thermocouple, is connected to the thermal process controller which transmits signals to control the amount of power directed to the furnace elements.
READ MORE: https://vacaero.com/information-resources/vac-aero-training/694-temperature-measurement-in-vacuum-furnaces.html
See lessWhat is back streaming and back migration in vacuum technology?
Back streaming and back migration are two phenomena that can occur in vacuum technology. Back Streaming: Back streaming refers to the movement of gas molecules from the high-pressure side of a vacuum system to the low-pressure side. This can happen when there is a pressure difference between two regRead more
Back streaming and back migration are two phenomena that can occur in vacuum technology.
Back Streaming:
Back streaming refers to the movement of gas molecules from the high-pressure side of a vacuum system to the low-pressure side. This can happen when there is a pressure difference between two regions of the system, causing gas molecules to flow in the opposite direction of the desired vacuum. Back streaming can occur through leaks, permeation through materials, or through the pumping system itself. It can lead to contamination of the vacuum environment and a decrease in the overall vacuum level.
Back Migration:
Back migration, also known as back diffusion, is the migration of gas molecules from the pump exhaust back into the vacuum chamber. This can happen when the pressure in the pump exhaust is higher than the pressure in the vacuum chamber. Back migration can occur due to the design of the pumping system, improper sealing, or inadequate pumping speed. It can result in the reintroduction of contaminants or unwanted gases into the vacuum chamber, affecting the quality of the vacuum.
Both back streaming and back migration are undesirable in vacuum technology as they can compromise the integrity of the vacuum environment and affect the performance of the system. Proper design, sealing, and maintenance of the vacuum system are important to minimize these phenomena and maintain a high-quality vacuum.
Source: Vacuum Technology and Vacuum Design Handbook” by Karl Jousten
See lessWhat are the consequences of back streaming and back migration in vacuum technology?
Back streaming and back migration in vacuum technology can have several consequences that can impact the performance and integrity of the vacuum system. Here are some of the consequences: 1. Contamination: Back streaming and back migration can introduce contaminants into the vacuum chamber. When gasRead more
Back streaming and back migration in vacuum technology can have several consequences that can impact the performance and integrity of the vacuum system. Here are some of the consequences:
1. Contamination: Back streaming and back migration can introduce contaminants into the vacuum chamber. When gas molecules flow in the opposite direction of the desired vacuum, they can carry particles, dust, or other contaminants from the high-pressure side or pump exhaust back into the vacuum chamber. This contamination can affect the quality and cleanliness of the vacuum environment, which is crucial in many applications such as semiconductor manufacturing or scientific research.
2. Decreased Vacuum Level: Back streaming and back migration can lead to a decrease in the overall vacuum level. When gas molecules flow from the high-pressure side to the low-pressure side, they increase the pressure in the vacuum system. This increase in pressure can reduce the effectiveness of the vacuum pump and compromise the desired vacuum level. It may require additional pumping or maintenance to restore the desired vacuum conditions.
3. Reduced Pumping Efficiency: Back streaming and back migration can reduce the efficiency of the vacuum pump. When gas molecules flow in the opposite direction of the pumping direction, they can interfere with the pumping process and reduce the pumping speed. This can result in longer pump-down times, decreased throughput, and overall reduced efficiency of the vacuum system.
4. Unwanted Gas Introduction: Back migration can result in the reintroduction of unwanted gases into the vacuum chamber. If the pressure in the pump exhaust is higher than the pressure in the vacuum chamber, gases from the pump exhaust can migrate back into the vacuum chamber. These gases may be contaminants or unwanted gases that can affect the process or experiment being conducted in the vacuum environment.
To mitigate the consequences of back streaming and back migration, proper design, sealing, and maintenance of the vacuum system are essential. This includes using appropriate materials, ensuring proper sealing of components, and selecting suitable pumping systems with adequate pumping speed and efficiency.
Source: Vacuum Technology and Vacuum Design Handbook” by Karl Jousten.
See lessWhat is backfill gas?
Backfill gas in vacuum heat treating refers to the process of introducing a gas into the vacuum chamber during the cooling phase of heat treatment. The purpose of backfill gas is to prevent the formation of unwanted oxides or other surface contaminants on the treated material as it cools down. VacuuRead more
Backfill gas in vacuum heat treating refers to the process of introducing a gas into the vacuum chamber during the cooling phase of heat treatment. The purpose of backfill gas is to prevent the formation of unwanted oxides or other surface contaminants on the treated material as it cools down. Vacuum furnaces can use a variety of different gases during the processing cycle in partial pressure operation, for backfilling to atmospheric pressure at the end of the processing cycle and for cooling/quenching. The most common of these gases (in order of frequency of use) are nitrogen, argon, hydrogen, and helium. Other common gases include various hydrocarbons and ammonia (for vacuum carburizing/carbonitriding) and specialty gases such as neon (for certain electronics applications).
During the heat treatment process, the material is heated to high temperatures in a vacuum environment to achieve specific metallurgical properties such as improved hardness, strength, or resistance to corrosion. After the desired temperature is reached and the material is held at that temperature for a certain period, it needs to be cooled down. Overall, the use of backfill gas in vacuum heat-treating helps maintain the integrity and quality of the treated material by preventing oxidation and surface contamination during the cooling phase.
Source: https://vacaero.com/information-resources/vac-aero-training/6488-types-backfill-partial-pressure-cooling-gases-vacuum-heat-treatment.html
See lessWhat is the impact of carbon buildup on the calibration of a thermocouple?
Carbon buildup on a thermocouple can have a significant impact on its calibration. Over time, the carbon deposits can change the electrical properties of the thermocouple, leading to a shift in the voltage output for a given temperature. This drift in calibration can result in inaccurate temperatureRead more
Carbon buildup on a thermocouple can have a significant impact on its calibration. Over time, the carbon deposits can change the electrical properties of the thermocouple, leading to a shift in the voltage output for a given temperature. This drift in calibration can result in inaccurate temperature measurements and affect the reliability of the thermocouple.
When a thermocouple is calibrated, it is typically done by comparing its voltage output to a known reference temperature. However, the presence of carbon buildup can interfere with the accuracy of this calibration process. The carbon deposits act as a barrier between the thermocouple and the surrounding environment, affecting the transfer of heat and altering the voltage output.
As the carbon buildup increases, the electrical resistance of the thermocouple can change, causing a deviation from the expected voltage output. This deviation can result in temperature readings that are lower or higher than the actual temperature, leading to inaccurate measurements.
To mitigate the impact of carbon buildup on the calibration of a thermocouple, regular cleaning and maintenance are essential. Cleaning the thermocouple to remove carbon deposits can help restore its accuracy and reliability. Additionally, periodic calibration checks and adjustments can be performed to ensure accurate temperature measurements.
It is important to note that the specific impact of carbon buildup on thermocouple calibration can vary depending on factors such as the type of thermocouple, the severity of the carbon deposits, and the operating conditions. Therefore, regular monitoring and maintenance are crucial to ensure the optimal performance of a thermocouple.
See less